Honeywell R8330D1039 Replaces the Electric Heat Sequencers listed below:
|
HONEYWELL |
|
CAM-STAT |
ROBERTSHAW |
TEXAS INSTRUMENTS |
R8330A |
R8330B |
R8330C |
S106 14-100 |
TDS-1 |
60000A 60700A |
R8330D |
R8330E |
R8330F |
S206 14-200 |
TDS-2 |
60000E 60704A |
R8330G |
R8330H |
R8330i |
S306 14-300 |
TDS-2-21 |
60200A |
R8330J |
R8330K |
R8206 |
S406 14-400 |
TDS-2-25 |
|
|
|
|
|
|
|
THERM-O-DISC |
|
|
WHITE - RODGERS |
|
|
11S1 |
11S2 |
|
24A11 |
24A51 |
|
11S1A |
11S2A |
|
24A12 |
24A52 |
|
|
|
|
24A14 |
24A53 |
|
|
|
|
24A20 |
24A54 |
|
|
|
|
24A21 |
24A55 |
|
|
|
|
24A22 |
24A56 |
|
HONEYWELL R8330D1039 24 Vac Electric Furnace Sequence.
One control switches a fan and up to three elements on and off in sequence.
Features
Isolated fan switch has positive interlock to assure fan is on when the element is on, and fan is off when the element is off.
Replaces any of the ten models in our line and many competitive devices.
Combination rating on the first element switch allows replacing devices having fan and first element controlled by the same switch without rewiring the furnace.
Auxiliary switch controls a second R8330 in application with more than three elements.
Sequencers connect by auxiliary switch to control up to nine heating elements
Isolated fan switch has positive interlock to assure fan is ON when the element is ON, and fan is OFF when the last element is OFF
Cycles ON within two minutes, OFF within four minutes.
Ten-second minimum delay between stages (makes sequence and break sequence.)
Combination rating on the first element switch allows replacement of devices having fan and first element controlled by the same switch without rewiring furnace
Timings meet EEI-NEMA and ARI 280 Standards
Quick-connect terminals and wiring accessories included for quick and easy wiring and installation
Ambient compensated for -20°F to +162°F
Meets or exceeds all industry standards
Mounts in any position
Thermostat current draw is constant (0.4A)
Dimensions: 4-13/16" W x 3-1/16" H x 2-11/31" D
|